MFP 1200 INPUT SPECIFICATIONS
|
|
MFP 1200 OUTPUT SPECIFICATIONS
|
| OPERATING VOLTAGE: |
Auto-ranging 85-250Vac |
PEAK DC OUTPUT: |
24~28Vdc @ 1.2kW |
| INPUT FREQUENCY RANGE: |
45~440Hz 90-260Vac |
CONT. DC OUTPUT: |
24~28Vdc @ 750W |
| INPUT CURRENT: |
15A Max |
MAX NORMAL OUTPUT CURRENT: |
50Adc @ 1.2kW |
| INRUSH CURRENT: |
In-rush Current Limiter |
PARD (20MHZ): |
< 50mVp-p/5mVrm |
| AC POWER CORD: |
1M or 2M (Optional) |
*Custom-tailored voltage ranges available. |
| EFFICIENCY (300W): |
>85% @ |
|
|
| PFC: |
> 95% @ Full Operating Power |
MFP 1200 SAFETY SPECIFICATIONS
|
MFP 1200 PACKAGING AND COOLING
|
| INPUT TO CASE ISOLATION: |
1500Vac |
COOLING: |
Sealed Convection |
| INPUT TO OUTPUT ISOLATION: |
1500Vac |
DIMENSIONS: |
16” X 7.5” X 3.5” |
| OUTPUT TO CASE ISOLATION: |
1500Vdc |
WEIGHT: |
15.3lbs |
MFP 300 PROTECTION FEATURES
|
| OUTPUT OVER-VOLTAGE: |
OVP @ 30Vdc (Red LED indicator) |
| OUTPUT OVER-CURRENT/SHORT CIRCUIT PROTECTION: |
Self-recovering Current Limiting Protection @ 60Adc (Red LED) |
| OVER -TEMPERATURE: |
OTP Protection @100°C Internal Temp.(Red LED) |
| INPUT OVER-CURRENT: |
In-rush Current Limiter |
| OPERATING TEMPERATURE: |
-40˚C~765˚C |
|
ENVIROMENTAL SPECIFICATIONS
|
| MIL-STD 810F |
Shock and Vibration |
| MIL-STD 461E |
EMC |
|