Bonafide Common Specifications1 |
| |
| |
| |
| Programming Accuracy (Basic & Premium) |
Programming/Measurement Resolution: 16-bit |
| Voltage: 0.05%*VOUT + 0.1% of FS |
|
| Current: 0.01%*IOUT + 0.1% of FS |
OVP Programmable Range: |
| Over-voltage: 0.2% of Vout + 0.3% of FS |
5% - 110% of VMAX |
| |
|
| Measurement Accuracy (Basic & Premium) |
Drift7 (8 Hours): |
| Voltage: 0.1% of RDG + 0.1% of FS |
CV Mode: 0.5%*VMAX |
| Current: 0.1% of RDG + 0.2% of FS |
CC Mode: 0.5%*IMAX |
| |
|
| Local & Ext. Programming Accuracy (Analog) |
Temp. Cofficient8: |
| Voltage (CV): ±0.5% |
CV Mode: 0.02%*VMAX / °C |
| Current (CC): ±1% |
CC Mode: 0.03%*IMAX / °C |
| |
|
| Load Regulation2 |
ac Input9: |
| Voltage: 0.01%*VMAX + 2 mV |
1Ф Wide PFC AC 85~265Vac | 45~440Hz |
| Current: 0.01%*IMAX + 2 mA |
|
| |
dc Output Isolation: |
| Line Regulation3 |
≤400Vdc: ±600Vdc |
| Voltage: 0.001%*VMAX + 2 mV |
≤600Vdc: ±1000Vdc |
| Current: 0.001%*IMAX + 2 mA |
≥800Vdc: ±1500Vdc |
| |
|
| Transient Response Time: 3ms5 |
|
| |
| *1: All electrical specifications are subject to change without prior notice |
| *2: Load regulation is specified for 10 - 90% load change |
| *3: Line regulation is specified for line voltage variation over the AC input voltage range with constant rated load |
| *4: Ripple and Noise (PARD) is specified for 10 - 95% output voltage @ full output current |
| *5: Time for output voltage to recover within +/- 0.5% of VFULL-SCALE following a 10% ~ 60% load current change |
| *6: Programming speed (Tup/Tdn) is specified @ 50% of full current loading |
| *7: Drift is specified over an 8-hour period with constant line, load, & temperature; after 30 minutes of warm-up |
| *8: Temperature coefficient is specified for changes in output/ °C in ambient temperature @ constant line & load |
| *9: AC Input Current will be greater than 15Amps @ AC Voltages below 100VAC |
| *9 For Safety compliance conformance (UL, CE etc.) ; Input AC Voltage Range: 100~240Vac @ 50/60/400Hz |