SPS1.2kW Legacy Series of Programmable Switching Power Supply Specifications (8Vdc~800Vdc) |
| Specifications1 |
SPS8-150 |
SPS20-60 |
SPS35-35 |
SPS40-30 |
SPS60-20 |
SPS80-15 |
SPS120-10 |
SPS150-8 |
SPS200-6 |
SPS300-4 |
SPS400-3 |
SPS450-2.5 |
SPS600-2 |
SPS600-2 |
| Number of Output |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
| Output Ratings |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Maximum Output Voltage (V)2 |
8.0 |
20.0 |
35.0 |
40.0 |
60.0 |
80.0 |
120.0 |
150.0 |
200.0 |
300.0 |
400.0 |
450.0 |
600.0 |
800.0 |
| Maximum Output Current (A)3 |
150.0 |
60.0 |
35.0 |
30.0 |
20.0 |
15.0 |
10.0 |
8.0 |
6.0 |
4.0 |
3.0 |
2.5 |
2.0 |
1.5 |
| Maximum Output Power (W) |
1200.0 |
1200.0 |
1200.0 |
1200.0 |
1200.0 |
1200.0 |
1200.0 |
1200.0 |
1200.0 |
1200.0 |
1200.0 |
1125.0 |
1200.0 |
1200.0 |
| Remote Programming Accuracy4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Voltage (0.2% Vmax + 10 mV) (mV) |
26 |
50 |
80 |
90 |
130 |
170 |
250 |
310 |
410 |
610 |
810 |
910 |
1210 |
1610 |
| Current (0.3% Imax + 10 mA) (mA) |
460 |
190 |
115 |
100 |
70 |
55 |
40 |
34 |
28 |
22 |
19 |
17.5 |
16 |
14.5 |
| Over-Voltage Protection (5% + 100 mV) (V) |
0.5 |
1.1 |
1.85 |
2.1 |
3.1 |
4.1 |
6.1 |
7.6 |
10.1 |
15.1 |
20.1 |
22.6 |
30.1 |
40.1 |
| Remote Programming Resolution5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Voltage (1.1 * Vmax / 65535) (mV) |
0.13 |
0.34 |
0.59 |
0.67 |
1.01 |
1.34 |
2.01 |
2.52 |
3.36 |
5.04 |
6.71 |
7.55 |
10.07 |
13.43 |
| Current (1.1 * Imax / 65535) (mA) |
2.52 |
1.01 |
0.59 |
0.50 |
0.34 |
0.25 |
0.17 |
0.13 |
0.10 |
0.07 |
0.05 |
0.04 |
0.03 |
0.03 |
| OVP (1.1 * Vmax / 65535) (mV) |
0.13 |
0.34 |
0.59 |
0.67 |
1.01 |
1.34 |
2.01 |
2.52 |
3.36 |
5.04 |
6.71 |
7.55 |
10.07 |
13.43 |
| Remote Readback Accuracy4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Voltage (0.2%*Vmax + 20 mV) (mV) |
36 |
60 |
90 |
100 |
140 |
180 |
260 |
320 |
420 |
620 |
820 |
920 |
1220 |
1620 |
| Current (0.3%*Imax + 20 mA) (mA) |
470 |
200 |
125 |
110 |
80 |
65 |
50 |
44 |
38 |
32 |
29 |
27.5 |
26 |
24.5 |
| Remote Readback Resolution5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Voltage (1.1 * Vmax / 65535) (mV) |
0.13 |
0.34 |
0.59 |
0.67 |
1.01 |
1.34 |
2.01 |
2.52 |
3.36 |
5.04 |
6.71 |
7.55 |
10.07 |
13.43 |
| Current (1.1 * Imax / 65535) (mA) |
2.52 |
1.01 |
0.59 |
0.50 |
0.34 |
0.25 |
0.17 |
0.13 |
0.10 |
0.07 |
0.05 |
0.04 |
0.03 |
0.03 |
| Local Meter Accuracy |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Voltage (0.5%*Vmax + 1 count) (mV) |
48 |
120 |
210 |
240 |
360 |
480 |
720 |
900 |
1200 |
1800 |
2400 |
2700 |
3600 |
4800 |
| Current (0.5%*Imax + 1 count) (mA) |
900 |
360 |
210 |
180 |
120 |
90 |
60 |
48 |
36 |
24 |
18 |
15 |
12 |
9 |
| Local & Ext. Analog Programming Accuracy |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Voltage and Current |
± 1% Rated |
± 1% Rated |
± 1% Rated |
± 1% Rated |
± 1% Rated |
± 1%
Rated |
± 1%
Rated |
± 1% Rated |
± 1% Rated |
± 1% Rated |
± 1% Rated |
± 1%
Rated |
± 1% Rated |
± 1% Rated |
| Load Regulation6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Voltage (0.02%*Vmax + 5 mV) (mV) |
6.6 |
9 |
12 |
13 |
17 |
21 |
29 |
35 |
45 |
65 |
85 |
95 |
125 |
165 |
| Current (0.03%*Imax + 5 mA) (mA) |
50 |
23 |
15.5 |
14 |
11 |
9.5 |
8 |
7.4 |
6.8 |
6.2 |
5.9 |
5.75 |
5.6 |
5.45 |
| Line Regulation7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Voltage (0.01%*Vmax + 2 mV) (mV) |
2.8 |
4 |
5.5 |
6 |
8 |
10 |
14 |
17 |
22 |
32 |
42 |
47 |
62 |
82 |
| Current (0.01%*Imax + 2 mA) (mA) |
17 |
8 |
5.5 |
5 |
4 |
3.5 |
3 |
2.8 |
2.6 |
2.4 |
2.3 |
2.25 |
2.2 |
2.15 |
| Ripple and Noise (20Hz~20MHz)8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Voltage RMS (rms) (mV) |
12 |
10 |
10 |
10 |
10 |
10 |
15.0 |
15.0 |
25.0 |
25.0 |
30 |
40 |
40 |
40 |
| Voltag P-P (0 - 20 MHz, p-p) (mV) |
75.0 |
70.0 |
50.0 |
50 |
50 |
75 |
150.0 |
150.0 |
300.0 |
300.0 |
350 |
350 |
400 |
400 |
| Transient Response Time (mS)9 |
3.0 |
3.0 |
3.0 |
3 |
3 |
3 |
3.0 |
3.0 |
5.1 |
5.1 |
3 |
3 |
3 |
3 |
OVP Adjustment Range
5% - 110% of Vmax (V) |
0.4 - 8.8 |
1 - 22 |
1.8 - 38.5 |
2 - 44 |
3 - 66 |
4 - 88 |
7.5 - 164 |
7.5 - 165 |
14 - 330 |
15 - 330 |
20 - 440 |
22 - 495 |
30 - 660 |
40 - 880 |
| Programming Speed (Tup/Tdn) (mS)10 |
100 / 100 |
100 / 100 |
100 / 100 |
100 / 100 |
100 / 100 |
100 / 100 |
169 / 170 |
170 / 170 |
169 / 170 |
170 / 170 |
170 / 170 |
170 / 170 |
170 / 170 |
170 / 170 |
| Temp. Cofficient11 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Constant Voltage (0.02%*Vmax / C) (mV/C) |
1.6 |
4 |
7 |
8 |
12 |
16 |
24 |
30 |
40 |
60 |
80 |
90 |
120 |
160 |
| Constant Current (0.03%*Imax / C) (mA/C) |
45 |
18 |
10.5 |
9 |
6 |
4.5 |
3 |
2.4 |
1.8 |
1.2 |
0.9 |
0.75 |
0.6 |
0.45 |
| AC Input |
115/230 VAC |
115/230 VAC |
115/230 VAC |
115/230 VAC |
115/230 VAC |
115/230 VAC |
115/230 VAC |
115/230 VAC |
115/230 VAC |
115/230 VAC |
115/230 VAC |
115/230 VAC |
115/230 VAC |
115/230 VAC |
| Frequency |
50 / 60 Hz |
50 / 60 Hz |
50 / 60 Hz |
50 / 60 Hz |
50 / 60 Hz |
50 / 60 Hz |
49 / 60 Hz |
50 / 60 Hz |
49 / 60 Hz |
50 / 60 Hz |
50 / 60 Hz |
50 / 60 Hz |
50 / 60 Hz |
50 / 60 Hz |
| DC Output Isolation |
± 600 V |
± 600 V |
± 600 V |
± 600 V |
± 600 V |
± 600 V |
± 600 V |
± 600 V |
± 600 V |
± 600 V |
± 600 V |
± 600 V |
± 600 V |
± 600 V |
| |
| *1: All electronic specifications are represented at the full operting temperature range for all models. |
| *2: Minimum voltage is guranteed to maximum 0.15% of the rated output voltage. |
| *3: Minimum current is guranteed to maximum 0.5% of the rated output current. |
| *4: The remote programming and readback accuracy specifications are guaranteed within 0.2% of rated voltage to maximum voltage, and 0.3% of rated current to maximum current value plus offset. |
| *5: The remote programming and readback resolution is based on 16 bit resolution |
| *6: Load regulation specifications are for 10 - 90% load changes. |
| *7: Line regulation specifications are for input voltage variation over the AC input voltage range, with constant rated load. |
| *8: Ripple and Noise specifications are for 10 - 100% output voltage and full output current. |
| *9: Time for output voltage to recover within +/- 0.5% of VFULL-SCALE following a 10% ~ 60% load current change. |
| *10: Programming speed specifications are for 50% of full current loading. |
| *11: Temperature coeffient speicifiations are for changes in output per °C change in ambient temperature, with constant line and load. |
| |
|