BENCH-TOP PROGRAMMABLE DC ELECTRONIC LOAD SPECIFICATIONS |
CV MODE SPECIFICATIONS |
|
CC MODE SPECIFICATIONS |
| CVL RANGE |
0 ~ 10% of VMAX |
CCL RANGE |
0 ~ 10% of IMAX |
| CVM RANGE |
0 ~ 50% of VMAX |
CCM RANGE |
0 ~ 50% of IMAX |
| CVH RANGE |
0 ~ 100% of VMAX |
CCH RANGE |
0 ~ 100% of IMAX |
| ACCURACY |
0.05% of Value ± 0.1% of Rating |
ACCURACY |
0.05% of Value ± 0.1% of Rating |
| RESOLUTION |
1/16000 of Rated Voltage |
CCUL RANGE |
0 ~ 10% of IMAX |
| TRANSIENT TIME (SLOW) |
0.250 ~ 255.9 (ms) |
CCUL ACCURACY |
0.05% of Value ± 0.05% of Range |
| TRANSIENT TIME (FAST) |
0.250 ~ 25.59 (ms) |
RESOLUTION |
1/16000 of Rated Current |
| |
|
TRANSIENT TIME (SLOW) |
0.250 ~ 255.9 (ms) |
CR and CP MODE SPECIFICATIONS |
TRANSIENT TIME (FAST) |
0.025 ~ 25.59 (ms) |
| Please reference website datasheet for details |
|
|
| |
|
|
GENERAL SPECIFICATIONS |
PROTECTION |
| REMOTE INTERFACES |
RS-232, GPIB & USB/ETHERNET |
OVER POWER PROTECTION |
110% * PMAX |
| ANALOG PROGRAMMING |
0 ~ 10Vdc |
OVER VOLTAGE PROTECTION |
105% * VMAX |
| ACCURACY |
Mode Accuracy ± 0.1% of Rating |
OVER CURRENT PROTECTION |
110% * IMAX |
| VMON ACCURACY |
0.10% of RDG ± 0.1% of Rating |
OVER TEMERPATURE PROTECTION |
90°C ± 5°C |
| IMON ACCURACY |
0.10% of RDG ± 0.1% of Rating |
REMOTE INHIBIT (RI) |
Short |
| IMON (CCUL) ACCURACY |
CCUL Mode Accuracy ± 0.1% of Rating |
FAULT INDICATOR |
SPDT Relay |
| FREQUENCY RANGE |
0.1Hz ~ 20kHz |
Other Programmable Protections: |
OPP, OVP, OCP, UVL & Anti-Oscillation |
| ACCURACY |
0.10% |
|
|
| AC INPUT |
95~240Vac 48 ~ 62Hz |
DIELECTRIC STRENGTH |
| OPERATING TEMPERATURE |
5°C ~ 40°C |
PRIMARY CIRCUIT TO CHASSIS |
1500Vac for 1 Minute |
| DIMENSIONS |
15.65" (L) x 8.35" (W) x 5.20" (H) |
PRIMARY CIRCUIT TO LOAD TERMINAL |
1500Vac for 1 Minute |
| WEIGHT |
22 lbs |
LOAD TERMINAL TO CHASSIS |
1500Vdc for 1 Minute |