ZERO-VOLT PROGRAMMABLE DC ELECTRONIC LOAD SPECIFICATIONS |
CV MODE SPECIFICATIONS |
|
CC MODE SPECIFICATIONS |
| CVL RANGE |
0 ~ 100% of Vmax |
CCL RANGE |
0 ~ 10% of Imax |
| ACCURACY |
0.2% of Value ± 0.1% of Rating |
CCM RANGE |
0 ~ 100% of Imax |
| RESOLUTION |
1/3600 of Rated Voltage |
ACCURACY |
0.2% of Value ± 0.1% of Rating |
| CV TRANSIENT TIME |
1ms ~ 273ms for 0Vdc to Vmax |
RESOLUTION |
1/3600 of Rated Current |
| |
|
CC TRANSIENT TIME |
27ms ~ 0.100ms for 0Adc to Imax |
CR and CP MODE SPECIFICATIONS |
|
|
| Please reference website datasheet for details |
PROTECTION |
| |
|
OVER POWER PROTECTION (OPP) |
110% * Pmax |
GENERAL SPECIFICATIONS |
RESOLUTION |
1/4000 of Rated Power |
| REMOTE INTERFACES |
RS-232 & GPIB |
ACCURACY |
1% of Setting ± 0.5% of Rating |
| CC MODE ANALOG PROGRAMMING |
0 ~ 10Vdc corresponds to 0 ~ Imax |
OVER VOLTAGE PROTECTION (OVP) |
110% * Vmax |
| ACCURACY |
Mode Accuracy ± 0.1% of Rating |
OVP RESOLUTION |
1/4000 of Rated Voltage |
| VMON ACCURACY |
0.10% of RDG ± 0.1% of Rating |
OVP ACCURACY |
0.20% of Setting ± 0.25% of Rating |
| IMON ACCURACY |
0.10% of RDG ± 0.1% of Rating |
OVER CURRENT PROTECTION (OCP) |
110% * Imax |
| AC INPUT |
115/230Vac | 50/60Hz |
OCP RESOLUTION |
1/4000 of Rated Current |
| OPERATING TEMPERATURE |
5°C ~ 40°C |
OCP ACCURACY |
0.20% of Setting ± 0.25% of Rating |